Data Management with FHIR
0.1.0 - ci-build France flag

Data Management with FHIR - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: Blood Pressure Measurement Method - XML Representation

Draft as of 2025-10-23

Raw xml | Download


<ValueSet xmlns="http://hl7.org/fhir">
  <id value="BloodPressureMeasurementMethod"/>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Narratif généré : EnsembleValeurs BloodPressureMeasurementMethod</b></p><a name="BloodPressureMeasurementMethod"> </a><a name="hcBloodPressureMeasurementMethod"> </a><p>Ce jeu de valeur (ValueSet) inclut les codes selon les règles suivantes :</p><ul><li>Inclut ce(s) code(s) tel quil(s) est (sont) défini(s) dans <a href="http://www.snomed.org/"><code>http://snomed.info/sct</code></a><span title="Version is not explicity stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href="http://snomed.info/id/77938009">77938009</a></td><td>Arterial pressure monitoring, invasive method (regime/therapy)</td></tr><tr><td><a href="http://snomed.info/id/17146006">17146006</a></td><td>Arterial pressure monitoring, non-invasive method (regime/therapy)</td></tr><tr><td><a href="http://snomed.info/id/37931006">37931006</a></td><td>Auscultation (procedure)</td></tr><tr><td><a href="http://snomed.info/id/765172009">765172009</a></td><td>Doppler ultrasound (procedure)</td></tr><tr><td><a href="http://snomed.info/id/13385008">13385008</a></td><td>Mediate auscultation (procedure)</td></tr><tr><td><a href="http://snomed.info/id/113011001">113011001</a></td><td>Palpation (procedure)</td></tr><tr><td><a href="http://snomed.info/id/31813000">31813000</a></td><td>Vascular oscillometry (procedure)</td></tr></table></li><li>Inclut ce(s) code(s) tel quil(s) est (sont) défini(s) dans <a href="CodeSystem-SolorTemporary.html"><code>https://interop.aphp.fr/ig/fhir/dm/CodeSystem/SolorTemporary</code></a><span title="Version is not explicitly stated, which means it is fixed to the version provided in this specification"> version &#x1F4E6;0.1.0</span><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Définition</b></td></tr><tr><td><a href="CodeSystem-SolorTemporary.html#SolorTemporary-911000205109">911000205109</a></td><td>Measurement of blood pressure using intravascular transducer (procedure)</td><td>A device that measures blood pressure intravascularly via a trandsducer.</td></tr><tr><td><a href="CodeSystem-SolorTemporary.html#SolorTemporary-641000205104">641000205104</a></td><td>Auscultation - automatic (procedure)</td><td>A procedure that uses a computer aided device to measure blood pressure.</td></tr></table></li></ul></div>
  </text>
  <url
       value="https://interop.aphp.fr/ig/fhir/dm/ValueSet/BloodPressureMeasurementMethod"/>
  <version value="0.1.0"/>
  <name value="BloodPressureMeasurementMethod"/>
  <title value="Blood Pressure Measurement Method"/>
  <status value="draft"/>
  <date value="2025-10-23T20:49:03+00:00"/>
  <publisher value="AP-HP"/>
  <contact>
    <name value="AP-HP"/>
    <telecom>
      <system value="url"/>
      <value value="https://aphp.fr"/>
    </telecom>
  </contact>
  <description
               value="SELECT SNOMED CT code system values that describe how a blood pressure was measured."/>
  <jurisdiction>
    <coding>
      <system value="urn:iso:std:iso:3166"/>
      <code value="FR"/>
      <display value="France"/>
    </coding>
  </jurisdiction>
  <copyright
             value="This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement"/>
  <compose>
    <include>
      <system value="http://snomed.info/sct"/>
      <concept>
        <code value="77938009"/>
        <display
                 value="Arterial pressure monitoring, invasive method (regime/therapy)"/>
      </concept>
      <concept>
        <code value="17146006"/>
        <display
                 value="Arterial pressure monitoring, non-invasive method (regime/therapy)"/>
      </concept>
      <concept>
        <code value="37931006"/>
        <display value="Auscultation (procedure)"/>
      </concept>
      <concept>
        <code value="765172009"/>
        <display value="Doppler ultrasound (procedure)"/>
      </concept>
      <concept>
        <code value="13385008"/>
        <display value="Mediate auscultation (procedure)"/>
      </concept>
      <concept>
        <code value="113011001"/>
        <display value="Palpation (procedure)"/>
      </concept>
      <concept>
        <code value="31813000"/>
        <display value="Vascular oscillometry (procedure)"/>
      </concept>
    </include>
    <include>
      <system
              value="https://interop.aphp.fr/ig/fhir/dm/CodeSystem/SolorTemporary"/>
      <concept>
        <code value="911000205109"/>
        <display
                 value="Measurement of blood pressure using intravascular transducer (procedure)"/>
      </concept>
      <concept>
        <code value="641000205104"/>
        <display value="Auscultation - automatic (procedure)"/>
      </concept>
    </include>
  </compose>
</ValueSet>