Guide d'implémentation du GT Standards et Interopérabilité pour les EDS - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
Mappings for the FrMedicationUcd resource profile.
FrMedicationUcd |
Medication | NewRx/MedicationPrescribed
-or-
RxFill/MedicationDispensed
-or-
RxHistoryResponse/MedicationDispensed
-or-
RxHistoryResponse/MedicationPrescribed |
code | coding.code = //element(*,MedicationType)/DrugCoded/ProductCode
coding.system = //element(*,MedicationType)/DrugCoded/ProductCodeQualifier
coding.display = //element(*,MedicationType)/DrugDescription |
manufacturer | no mapping |
form | coding.code = //element(*,DrugCodedType)/FormCode
coding.system = //element(*,DrugCodedType)/FormSourceCode |
ingredient | |
item[x] | coding.code = //element(*,MedicationType)/DrugCoded/ProductCode
coding.system = //element(*,MedicationType)/DrugCoded/ProductCodeQualifier
coding.display = //element(*,MedicationType)/DrugDescription |
batch | no mapping |
lotNumber | no mapping |
expirationDate | no mapping |
FrMedicationUcd |
Medication | |
code | RXO-1.1-Requested Give Code.code / RXE-2.1-Give Code.code / RXD-2.1-Dispense/Give Code.code / RXG-4.1-Give Code.code /RXA-5.1-Administered Code.code / RXC-2.1 Component Code |
coding | C*E.1-8, C*E.10-22 |
text | C*E.9. But note many systems use C*E.2 for this |
manufacturer | RXD-20-Substance Manufacturer Name / RXG-21-Substance Manufacturer Name / RXA-17-Substance Manufacturer Name |
form | RXO-5-Requested Dosage Form / RXE-6-Give Dosage Form / RXD-6-Actual Dosage Form / RXG-8-Give Dosage Form / RXA-8-Administered Dosage Form |
amount | N/A |
ingredient | |
item[x] | RXC-2-Component Code if medication: RXO-1-Requested Give Code / RXE-2-Give Code / RXD-2-Dispense/Give Code / RXG-4-Give Code / RXA-5-Administered Code |
strength | N/A |
batch | |
lotNumber | RXA-15 Substance Lot Number / RXG-19 Substance Lot Number |
expirationDate | RXA-16 Substance Expiration Date / RXG-20 Substance Expiration Date |